Where required by the authority having jurisdiction, hydrostatic tests shall be permitted to be completed in accordance with the requirements of AWWA C600, AWWA C602, AWWA C603, and AWWA C900. Through 60 In. (76 mm), for Water Service. BURIED POLYVINYL CHLORIDE (PVC) SEWER AND PRESSURE PIPE Page 3 of 6 2. Schedule 40 is used in applications, such as irrigation, underground residential sprinkler systems, water service pipe, deionized water lines, swimming pool installations, and some chemical drainage systems. ASSEMBLING THE PIPE Assembly of Vinyltech PVC water pipe is easily accomplished. pipe and joint inspections. DIMENSIONS OF PIPE (Sec. AWWA C901 Polyethylene (PE) Pressure Pipe and Tubing, 1/2 In. Burst test pressure capability of C900 Class 150 is at least 755 psi, with sustained pressure test capability of 500 psi. Pipe Requirements N-12 Low Head pipe shall have a smooth interior and annular exterior corrugations. DO NOT CUT PIPE!. Provide pressure relief holes at close enough intervals to prevent buckling of pavement/sidewalks. The required pipe relaxation period, if any, will commence after the initial pressure test is successfully completed. Collapse pressure (or PVC pipe crush strength) is the amount of outside pressure a pipe can take before it starts collapsing inwards. Pipe: ASTM F 679, T-1 wall thickness, bell and spigot for gasketed joints. 31 AWWA C651-14 Disinfecting Water Mains. Through 60 In. Leakage is defined as the quantity of water that must be supplied into the main in order to maintain the water pressure within 5 psi. The test duration shall be 2 hours. What is C900 PVC pipe? C900 is the American Water Works Association (AWWA) standard for cast-iron-pipe-equivalent outside diameter PVC pressure pipe and fabricated fittings covering nominal pipe sizes from 4 inches through 12 inches. One thing that has often confused users (whether I’m talking with engineers, distributors or contractors) is the difference between “Thickness Class” and “Pressure Class” pipe. Fire Hydrants. GENERAL INFORMATION Plastic C900 water pipe consist of the mains and branches that serve residential, commercial, and industrial structures. Plastic piping approved for underground installations shall be PVC, C900, Class 150 or greater, and be listed for such use. Ductile Iron Pipe and fittings may be used for force mains 8 inches and larger: a. Pipe testing is performed in accordance with ASTM D1598, Time to Failure of Plastic Pipe Under Constant Internal Pressure. POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900) STD SPEC 15292 - 2 C. Fusible C-900 ® pipe and Fusible C-905 ® pipe both comply with the AWWA standards AWWA C900 and C905 respectively and are certified to NSF 61. (13 mm) – Through 3 In. The test pressure is never less than the designed operating pressureThe maximum hydrostatic test pressure is based. FITTINGS Ductile Iron (Mechanical Joint, Flanged, Push-On) PVC (SCH 40/80, C900/200 Pressure, Sewer D3034) Carbon Steel. The Style 77B repair clamp is available with three different size cone gaskets (See chart below). Hydrostatic Testing, AWWA C600. Recent industry discussions have included S4 testing for water applications as well. As a result, for a given flow and nominal size of pipe, cement-mortar-lined, minimum pressure class Ductile Iron pipe typically experiences less head loss than alternate material pipelines. May be used for force mains in diameters 12-inch and smaller as an alternative to DIP if the PVC pipe meets the external load and internal pressure requirements, as stated in this section. Check List: Making Joints with PE Pipe 13 Pressure Testing 13 Disinfection 13 Appendix 14 Dimension Ratio 14 Table 3: PE Water Service Pipe Pressure Rating versus Product SDR or SIDR 15 Table 4: Pressure Ratings (PR) for Elevated Temperatures 15 Table 5: Pipe Made to Standard Outside Diameters 16 Table 6: Tubing Made to Standard Outside. North American Pipe Corporation’s AWWA C900 Gasketed Integral Bell PVC Pipe product line is manufactured to meet the needs of modern municipal water, wastewater, and reclaimed. We hereby certify material furnished by U. AWWA C901 Polyethylene (PE) Pressure Pipe and Tubing, 1/2 In. PVC Pressure Pipe. Burst test pressure capability of C900 Class 150 is at least 755 psi, with sustained pressure test capability of 500 psi. † Number of taps on pipe based on discharge through 5' of galvanized pipe with one 90° elbow. Testing was conducted on DR18 AWWA C900 PVC pipe. Falling Weight Impact Test At 73˚F, C900 withstands an impact energy of 150 ft-lbs, when tested in accordance with ASTM D 2444. Schedule 40 is used in applications, such as irrigation, underground residential sprinkler systems, water service pipe, deionized water lines, swimming pool installations, and some chemical drainage systems. AWWA C900-07 standard states: 5. • After the pipe has been joined, fill it with water, carefully bleed off any trapped air. It’s light weight and ease of installation, coupled with its dependability and long life span has made it the pipe of choice for the last 20 years in irrigation. Corporation curb stop taps used for flushing, pressure testing, and disinfecting shall comply with service tap requirements for ductile iron pipe or C900 PVC pipe. Polyvinyl Chloride (PVC) Pressure Pipe, and Fabricated Fittings 4 in. SECTION 33 11 00 WATER UTILITY DISTRIBUTION PIPING PART 1 GENERAL 1. and pull the washover pipe along the drilled path, with the pipe following slowly behind. C300 pipe is manufactured using a welded steel cylinder welded to steel joint rings and mild steel reinforcing cage(s). Both ductility and resistance to internal pressure are still on the same level as new pipes. *This is highlighted testing on common sizes. Outlet sealed tapping sleeves for C900 O. The appropriate drilling machine with equipment for the size of connection and type of pipe makes it easy to drill the main through the open corporation valve. AWWA C900/IB PVC Pressure Pipe NAPCO’s AWWA C900 Gasketed Integral Bell PVC Pipe product line is manufactured to meet the needs of modern municipal water, wastewater, and reclaimed water systems. Testing and Disinfecting Water Mains 1-2 2/5/2015. Test PVC Pipe mains in accordance with ANSI/AWWA C605-once all backfill is in place and fully compacted, and after all thrust blocks, if applicable, have cured to their design strength. 3 PVC PRESSURE PIPE A. manufacturing and installing Vinyltech AWWA C900-07 water pipe. C905 refers to the pipe as “pressure rating. C900-89: AWWA Standard for Polyvinyl Chloride (PVC) Pressure Pipe, 4 In. Also listed for PVC C900 pipe at the pressure rating of the pipe. mm)-diameter polyvinyl chloride pipe with a minimum wall thickness of 0. 2, Table 1 of AWWA. 5 times the design pressure limit the of the unit. AWWA C900 PVC pipe is manufactured in three "pressure classes" (100, 150, and 200). TESTING INFORMATION* northweSt teSting LaBoratory; Port Land, oregon REfERENcE DOcUMENT: ASTM D3212 A 4” INSERTA TEE was installed into an 8” profile pipe with the following results: • Pressure @16. Burst test pressure capability of C900 Class 150 is at least 755 psi, with sustained pressure test capability of 500 psi. Burst test pressure capability of C900 Class 150 is at least 755 psi, with sustained pressure test capability of 500 psi. 5 million cycles of pressure changes from 100 psi to 200 psi during a period of 2 seconds for each cycle. This analysis in no way suggests that any or all plastic pipe failures occur in the manner described. 5 times the system design pressure for a maximum of. 5 inches to 8 inches, and for AWWA Standard C900 pipes that are compatible with cast iron pipe sizes 4 inches to 8 inches. Compared to conventional PVC pipes, the new product called C900 is designed to withstand extremely high hydrostatic pressure on testing. Both ductility and resistance to internal pressure are still on the same level as new pipes. Be sure pipe is centered inside the sleeve. water distribution pipe and couplings conforming to AWWA C900. The S4 test was originally developed for the natural gas industry using air as the test medium. through 12-in. Thus, the dimensions and performance of the joint resemble those established for the pipe and will in turn exhibit identical performance characteristics. (350 mm Through 1200 mm), 2010. AWWA C605-2013 Underground Installation Of Polyvinyl Chloride (Pvc) Pressure Pipe & Fittings For Water. The Chrysotile Institute estimates AC pipe lifespan at 70 years, but actual service life depends largely on pipe condition and working environment. Testing was performed to evaluate how pipelines composed of iPVC pipe accommodate large ground deformation. Part Two, Section 24. (100 mm through 1,200 mm) polyvinyl chloride (PVC) pressure pipe and fabricated fittings. Specifically, it is concerned with issues such as permeation, pressure tolerance, and quality control. ) This standard covers 4-in. A total of 44 pipe products were added to the 93 already included in the C900-07/C905-10 product mix, so C900-16 now includes 137 pipe options. The restrained joint pipe system shall also meet all short and long term pressure test requirements of AWWA C900. The length of fire hydrant laterals and service lines are not included in the overall length of pipe in determining the allowable leakage. • 30- through 60-inch (750 to 1500 mm) shall meet AASHTO M294, Type S or ASTM F2306 with the. Hydrostatic Testing, AWWA C600. (Hydrostatic integrity. (2) PVC pipe downstream of a PRV may be Pressure Class 150 (DR-18). The work covered by this Section relates to waterlines and appurtenances including pipe material permitted, installation, testing, and cleanup. The pipe, including any integral bell end or affixed coupling, shall not fail, balloon, burst, or weep when subjected to an internal pressure equal to 2. Find C900 PVC Pressure Pipe Fittings related suppliers, manufacturers, products and specifications on GlobalSpec - a trusted source of C900 PVC Pressure Pipe Fittings information. Standard pipe outside diameters (ODs) conform to the ductile iron and cast iron sizing system, referred to as cast iron or CIOD, and steel pipe, referred to as IPS (iron pipe size). Pipe Underground Plastic C900. Get the best deals on Unbranded Parts for Ford C900 when you shop the largest High Pressure Car Wash Water Gun Accessories 3600PSI Tool Signal Converter Test. C900 pipe is delivered in standard laying lengths of 20 feet +/- 1 Inch. Wall Coupling % Change in Bend Radius Pull (No Bending). 12-1 Metric Version It is the designers responsibility to recommend a test pressure appropriate for the piping system. The number of projects completed by pipe bursting is much greater than pipe reaming. its quick burst strength. (100 mm Through 1,650 mm), for Waterworks; AWWA M55: Manual for the Design and Installation of Polyethylene Pipe in water Applications. All pipe shall be tested in the United States in accordance with AWWA C900 and certification of the testing shall be furnished to the engineer upon his request prior to delivery. Compared to conventional PVC pipes, the new product called C900 is designed to withstand extremely high hydrostatic pressure on testing. Browse the three supercategories and over 60 subcategories below for services such as fire hydrant flow testing & flushing and wastewater treatment services and products such as ductile iron pipe fittings, analyzers, and meter locking devices to help you run your water works more efficiently. Pipe: AWWA C900, Class 150 Class 200 PVC pipe with bell-and- spigot ends for gasketed joints. Fire Hydrants. Polyvinyl Chloride (PVC) Pressure Pipe, 4 in. Using factory insulated pipe as a guide, cut back insulation and bevel pipe (simultaneously removing burrs, cuts, nicks, and scratches) using a PVC pipe beveller, a hand rasp, or file to a 15 degree bevel. Field test report for each backflow prevention device. The appropriate drilling machine with equipment for the size of connection and type of pipe makes it easy to drill the main through the open corporation valve. PVC pressure pipe made from class 12454-A or class 12454-B material providing a hydrostatic design basis (HDB) of 4000 psi and with cast-iron-pipe-equivalent (CI) outside diameter (OD) dimensions and with wall thicknesses equivalent to a dimension-ratio (DR) series 14, 18, or 25. HYDROSTATIC PRESSURE TESTING OF PIPING (PROJECT STANDARDS AND SPECIFICATIONS) Page 3 of 19 Rev: 01 July 2011 Minimum Test Pressure - The lowest allowable test pressure gauge reading (the calculated test pressure plus the additional pressure resulting from the static head of the test fluid). Nov 25, 2019 · bid codes description units; 7021 6059: 24" casing by open cut notes:otu lf: 7021 6060: 8" sewer pipe notes:otu lf: 7021 6061: 8" dip sewer, css backfill notes:otu lf: 7021 6062. Mueller service saddles are compatible with Mueller® drilling machines and corporation valves. Pressure Ratings (PSI) HDPE Pipe C900 PVC Pipe C905 PVC Pipe The Series 3800 are designed to restrain forces based on the maximum working pressure ratings listed in the Pressure Ratings Table. 33 AWWA C800-14 Underground Service Line Valves and Fittings. through 60-in. In this bulletin we will explore the effects of temperature on PVC pipe. THE PRESSURE RATING OF SCHEDULE PIPE DECREASES AS THE SIZE INCREASES. Fittings: ASTM F679 3. (100 mm - 300 mm), for Water Transmission and Distribution. Throughout the country, in all conditions and climates, C900 has. Click to find out about Fiberglass pipe products and uses. C905 is a comparable standard for potable water PVC pressure pipe, designed for pipe and fittings with nominal sizes over 12 inches. needed for field alterations (include pipe for bell or socket) and cut through pipe unit with a fine tooth saw or abrasive saw. through 212 in. Standard Thermoplastic Testing Methodology. The test pressure shall not be less than 150 psi at the highest point. Pipe shall be furnished with integral bells. Pipe Tensile Test • Two tests performed with spigot completely inserted into the bell • Six 0. (100mm Through 300mm), for Water Transmission and Distribution AWWA C605 - Underground Installation of Polyvinyl Chloride (PVC) Pressure Pipe and Fittings for Water. Burst test pressure capability of C900 Class 150 is at least 755 psi, with sustained pressure test capability of 500 psi. pressure class 350. (350 mm Through 1200 mm), 2010. The high pressure test plug ensures that pipe work isolations can be undertaken safely using our proven Grip-lock TM and Posi-seal TM technologies. PVC pipe) • 1000 Hour Sustained Pressure Test - per ASTM D1598 at 500psi (DR18) for 10x the ASTM threshold of 1000 hours -UGSI test duration was 10,000 hours -fused and un-fused pipe • 1,000,000 Cycle Pressure Test -(94-188psi for DR18) demonstrating cyclic surge on a fused joint system per ASTM F1674 -simulating a severe duty. scope: This standard describes underground installation and hydrostatic testing procedures for polyvinyl chloride (PVC) or molecularly oriented polyvinyl chloride (PVCO) pressure pipe and fittings that comply with either ANSI*/AWWA C900, ANSI/AWWA C905, ANSI/AWWA C907, or ANSI/AWWA C909. AWWA C900-07 Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. the nominal diameter of the pipe, in inches; and P is the average test pressure during the leakage test, in pounds per square inch gauge. DR18 Pressure Pipe AWWA C900 8 in. The length of pipe is sealed at each end, filled with water, pressurized, depressurized, and then packaged. AWWA C906 takes into account the continuous pumping and transient (surge) pressures that occur in municipal water pipes. pressure class selection per awwa c906 Selecting the right pressure class for high density polyethylene pipe (HDPE) in accordance with AWWA C906 can be done in two easy steps. The unique lip seal design seals on even rough pipe surfaces. There are no additional components that are needed. , for Water Distribu on". Corrosion Proof Made of noncorroding PVC, Blue Brute fittings will not rust or corrode in aggressive soils. 5 time Please share you thoughts. Embedment material can be used to centre load the pipe and prevent movement. An inflatable test ball is inserted into building or home main line sewer cleanout and is then inflated in order to block or plug the main sewer line. This is the September 2019 plastic pipe blog that covers one of the largest HDPE pressure pipes in North America, ocean cleanup updates, a renewable energy system made from PEX pipe, and the upcoming Pexco extrusion acquisition. 5 times the pipe's pressure rating for recurring surge and 2. (19 mm) Through 3 In. 5), 100 psi (DR 41), and 80 psi (DR 51). Watermains are pressure pipe systems so they are more adaptable to underground or above ground obstructions (via fittings) than gravity pipe systems. Pipe shall be furnished with integral bells. through 48 in. for strength by burst testing. United States Pipe and Foundry Company’s ductile iron pipe meets or exceeds the requirements of the national standards listed above that relate to pipe manufacture and component performance. its quick burst strength. A graphical depiction of the flow rate (usgpm) and the hydraulic loss for 12” DIPS DR18 PVC and 12” DIPS DR17. Wall Coupling % Change in Bend Radius Pull (No Bending). Every pipe and machined coupling shall pass the AWWA C900 hydrostatic proof test requirements of 2 times the pressure class for 5 seconds. 7 Applicable Standards (use latest version) 1. Each piece of C900 pipe is manufactured into 20-foot lay lengths. Restraint devices for securing PVC pipe bell assemblies shall be SIGMA PV-LOK™ Series. (100 mm Through 300 mm), for Water Transmission and Distribution. The pipe section to be tested is then filled with test water. 01 Revised 11/16/2009 Page 2 of 2 210100 system. AWWA C906 – Polyethylene Pressure Pipe and Fittings, 4-In. Oct 10, 2013 · The plaintiff in the JM Eagle class action claims that he bought the JM Blue Brute C900 PVC pipe, which contained a UL Mark, indicating that it passed a number of tests, including one measuring longitudinal tensile strength (LTS); however, all of the Blue Brute pipes manufactured between 1997 and 2005 did not pass the LTS test, according to the. All pipe shall have the same outside dimensions as ductile-iron pipe. Mueller service saddles are compatible with Mueller® drilling machines and corporation valves. (350 mm Through 1200 mm), 2010. AWWA C900-07 Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. divided by the wall thickness B. Provide follower gland using breakaway torque bolts to engage thrust restraint. The size of tap is restricted to ¾" or 1 inch. Read the history of FRP products and their common usage, find out about codes and standards, Fiberglass Tank & Pipe Institute's members of underground fiberglass tank manufacturers and services. RIGID POLYVINYL – CHLORIDE (PVC) PIPE (ASTM D1785, NSF # 14) E. total allowable leak loss. C900-81, "AWWA Standard for Polyvinyl Chloride (PVC) Pressure Pipe, 4-inch through 12-inch, for Water:" PVC pipe fourteen inches (14”) and larger shall be manufactured in accordance with AWWA C905-88, "AWWA Standard for Polyvinyl Chloride (PVC) Water Transmission Pipe, Nominal Diameters. • After the pipe has been joined, fill it with water, carefully bleed off any trapped air. 1 SIZES, SPECIFICATIONS, AND PRESSURE RATINGS OF IPVC PIPE The iPVC pressure pipe is manufactured using ASTM D1784 PVC compounds and cell classification 12454 materials. Burst test pressure capability of C900 Class 150 is at least 755 psi, with sustained pressure test capability of 500 psi. UGSI's Fusible PVC ® products contain a proprietary PVC formulation that, when combined with UGSI's patented fusion process, results in a monolithic, fully-restrained, gasket-free, leak-free piping system. Pipe Tensile Test • Two tests performed with spigot completely inserted into the bell • Six 0. Fully dimensioned drawings of piping layouts, including fittings, couplings, sleeves, cleanouts, valves, supports and anchors. Through 12 in. • Listed with Underwriters Laboratories in sizes 4" to 12" for use on DR18 PC235 C900 PVC pipe at 235 PSI. Bolts and nuts to be Type 304 stainless steel. Thrust Blocking. Dimensions, pressure capacity, and stiffness are all affected by temperature changes. ping of PVC Pressure Water Pipe (Nominal ditional test requirements as described in AWWA C900-07 VINYLTECH PVC¥PIPE VINYLTECH AWWA C900-07. The iPVC pipes are available in diameters 4, 6, 8, 10 and 12 inches and manufactured in accordance to with AWWA C900 and ISO guidelines. (100 mm Through 300 mm), for Water Distribution Created Date. 6" PVC Stargrip® Series 4000G2 for PVC Pipe Increased. the nominal diameter of the pipe, in inches; and P is the average test pressure during the leakage test, in pounds per square inch gauge. In this paper presentation, we take a deep dive into what it takes to. The pipe features the BullDog internal joint restraint system and eliminates the need for external clamping devices. During the hydrostatic proof tests, each length of pipe is tested at twice the pressure rating of the pipe for a minimum dwell of 5 seconds. It is important to know that pipe and fitting manufacturers do not recommend air testing and cannot be held liable for any injuries occurring during the air testing of their product. Ultra Pressure Components services a wide variety of Industries with a wide product range. 5 safety factor. To test this type of strength, you can place weight on a pipe until it starts buckling. 1 ANSI/AWWA C110/A21. 13 - 7 Tapping Sleeves Tapping sleeves shall have a stainless steel body and flanged outlet. The requirement refers to the working pressure of the pipeline, i. C900 – AWWA Standard for Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 Inch Through 12 Inch, for Water Distribution. Siloam Springs, Arkansas. Pipe, couplings, and locking splines shall be completely non-metallic to eliminate corrosion problems. The test duration shall be 2 hours. 2 b) AWWA C900 PVC. The requirement refers to the working pressure of the pipeline, i. ii) Sizes 14-inch to 30-inch shall meet all the dimensional, chemical, and physical requirements. It should be remembered that the hydrostatic test is done using the pipe’s own gasket, which means that both the pipe and the joining system are being checked. (2) PVC pipe downstream of a PRV may be Pressure Class 150 (DR-18). Air in the line during a water pressure test will keep compressing the air, thus allowing it to escape around the rubbers, until most of the air is gone the pipe will not hold 200lbs, which is the test pressure here and I believe throughout most of the country. (1575 mm) for Water Distribution AWWA C906. • After the pipe has been joined, fill it with water, carefully bleed off any trapped air. Browse other construction projects for bid. 5 times the working pressure or 125 psi, whichever is greater. surging pressure. AWWA C900-2016 Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. Pressure classes range from 80 psi (550 kPa) to 305 psi (2,100 kPa). With top quality raw materials and modern processing technology, our C900 pipe meets all industry standards in addition to our own rigorous quality. These fitting are available for sewer pipe sizes 4 inches to 15 inches, for IPS-PVC pipe sizes 1. 1 ANSI/AWWA C110/A21. When the ambient temperature is higher than 77f the test pressure shall be reduced using Table 4. non-potable, re-use, effluent) shall be purple in color. The pressure is then held for a specific amount of time to visually inspect the system for leaks. Hydrostatic integrity test pressure (example, T330) f. offers a full range of NSF 61 and Annex G certified mechanical joint tapping sleeves and crosses to fit most types of pipe, including cast iron, ductile iron, A-C and cast iron O. 20 Minimum Wall Thickness. Size range is 4- to 12-inch nominal pipe size. INJECTION-MOLDED FITTINGS Injection-molded fittings are manufactured by injecting PVC compound intocavity a mold per AWWA C907. Markings on the Pipe Identification of nominal pipe size (CI diameter), PVC, dimension ratio, ANSI/AWWA pressure class, test pressure for hydrostatic tested pipe, AWWA. Includes 53 different calculations. Prabhat Industries LLC. This section covers sanitary sewer. northernpipe. Collapse Pressure. GENERAL INFORMATION Plastic storm sewer pipe consists of mains, catch basin branches, curb inlet branches, field tiles, roof drain laterals, etc. In plan layout of pressure networks, when drawing a pipe you can enter to draw a curve, the same way as when you draw a polyline for curved segments. It is important to know that pipe and fitting manufacturers do not recommend air testing and cannot be held liable for any injuries occurring during the air testing of their product. C900, DR 18 or C909 (150 PSI), with pipe made to ductile iron outside diameters. 3 PVC PRESSURE PIPE A. 3 Do not use PVC pipe that is more than 24 months old. In this paper presentation, we take a deep dive into what it takes to. The test pressure is printed on the pipe for reference. The S4 test was originally developed for the natural gas industry using air as the test medium. pipe at the specified depth below the surface. ANSI/AWWA C901-17 Polyethylene (PE) Pressure Pipe and Tubing, 3/4 In. We are well connected with a wide network of product testing laboratories and industry experts. To begin the test, note the exact time and reading on the gauge. Markings on the Pipe: Identification of nominal pipe size (CI diameter), PVC, dimension ratio, AWWA pressure class, test pressure for hydrostatic tested pipe,. ” Pressure Test Modify Replace this subsection with, “The test pressure shall be maintained at. The maximum working pressure of groove pipe joint with nominal diameter of DN300 or more is 1. Pressure Class is formed using a 2. , for Water Distribution AWWA C900 Polyvinyl Chloride (PVC) Pressure Pipe, 14 in. Find C900 PVC Pressure Pipe Fittings related suppliers, manufacturers, products and specifications on GlobalSpec - a trusted source of C900 PVC Pressure Pipe Fittings information. View the most recent version. This standard describes polyethylene (PE) pressure pipe and tubing made from material having standard PE code designations PE 2606, PE 2706, PE 2708, PE 3608, PE 3708, PE 3710, PE 4608, PE 4708, and PE 4710 and intended for use in potable water, reclaimed water, and wastewater service. Watermains are pressure pipe systems so they are more adaptable to underground or above ground obstructions (via fittings) than gravity pipe systems. May be used for force mains in diameters 12-inch and smaller as an alternative to DIP if the PVC pipe meets the external load and internal pressure requirements, as stated in this section. C900-97 Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 in. Each zone shall have a control valve, flow switch, pressure gauge and test drain connection. Item Acceptable Manufacturers/Product Minimum Specifications for Alternative Manufacturers PVC Pipe Diamond Plastics/ C900 AWWA C-900, DR-14, Sizes 4"-12". Today's flow test is going to include some basic hydraulic calculations so we can determine the adequacy of water for a new grocery store (Ordinary Hazard Group II Occupancy) that will need between 575 and 675 gpm. We carry no-lead brass, water hydrants, ductile iron and PVC piping. Each length of Blue Brute, IPEX Centurion and TerraBrute pipe is hydrostatically tested in order to verify the pressure capabilities of each pipe as dictated by AWWA C900 and C905. The cast iron or ductile iron fittings shall be mechanical joint, except as noted, with a. For DR18 pipe, that pressure is 500 PSI. A hot tap saddle or weld nozzle installed, valve installed, assembly is pressure tested and hot tap machine attached. If the insert valve is moved the pressure test must be completed again. AWWA C905. A d d e n d u m shall be well flushed and pass the pressure test per part 4. 12 Hydrostatic proof test for pipe. Benefits: JM Eagle Blue Brute C900 pipe is the safe, long-lasting and stable solution for a modern infrastructure. During the test, subject pressure sewer lines to a hydrostatic pressure of 100 psi. 03) The sizes of PVC pressure pipe shown on the drawings or as specified either refer to inside diameters and standard dimension ratios (SDR) conforming to ASTM D2241, or refer to inside diameters and dimension ratios (DR) conforming to AWWA C900 with cast iron pipe equivalent O. Approximately 11,644 linear feet of 16-inch diameter buried PVC Pressure Class 235 pipe (C900-16 DR18); Approximately 8,627 linear feet of 16-inch diameter buried restrained joint PVC Pressure Class 235 pipe (C900-16 RJ DR18) Certa-Lok, Eagle Loc, BullDog, Fusible PVC or an approved equal;. Each length of AWWA marked PVC pipe is individually pressure tested. Do not test against closed valves. The key elements of force mains. Label pipe size, materials, type, and class on drawings and include the limits of each reach of restrained joints. AWWA C900 (2016) Polyvinyl Chloride (PVC) Pressure Pipe, and Fabricated Fittings, 4 In. Bliesnervii in addition to the earlier, FHA and the Soil Conservation Services recommend a working pressure of fittings to be held at 60% to 72% of the static pressure rating of the pipe as a useful guide for PVC piping design. In the case of the 25 bar pipe, the axial test force is on the order of 1200 ton since the test pressure is 1. (1) Pipe dimension ratio for AWWA C900 PVC. Air pressure begins to drop in the system as a result of the open inspectors test valve. Blue Brute injection-molded pressure fittings have wall thicknesses at least 25% greater than DR18 pipe of the same size. through 48 in. The engineer may be present during physical testing of pipe. Air in the line during a water pressure test will keep compressing the air, thus allowing it to escape around the rubbers, until most of the air is gone the pipe will not hold 200lbs, which is the test pressure here and I believe throughout most of the country. , for Water Distribution, 2007. that ductile iron pipe is made to. AWWA C900-16 Polyvinyl Chloride (PVC) Pressure Pipe & Fabricated Fittings 4"- 60": This standard covers 4-in. 34 AWWA C900-16 Polyvinyl Chloride (PVC) Pressure Pipe, 4 in. This paper discusses the test methodology, test results, and the accurate and updated conclusions for modern PVC pressure pipe made to AWWA C900. American Society of Testing and Materials (ASTM): 1. Part Two, Section 24. In addition, new sizes and pressure ratings of PVC pipe. (50 mm) of pullout before engagement. National Sanitation Foundation (NSF): 1. Until such time as UL standards are harmonized with AWWA, UL requirements shall be used, which are 4 times the UL pressure class for 5 seconds (4*150=600psi, 4*200=800psi). Testing and Disinfection, 15140-1 Rev. The hydrostatic proof test is performed on every piece of PVC pipe and machined fitting is tested to a minimum dwell time of 5 seconds. Included in this standard are criteria for classifying PE plastic pipe materials, a system of nomenclature for PE plastic pipe, and requirements and test methods for materials, pipe, and tubing. Each valved section of pipe shall be slowly filled with water, and the specified test pressure (based on the elevation of the lowest point of the line or section under test and corrected to the elevation of the test gauge) shall be applied by means of a pump connected to the pipe. AWWA C900 – Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. A hydrostatic test is a way in which pressure vessels such as pipelines, plumbing, gas cylinders, boilers and fuel tanks can be tested for strength and leaks. Collapse Pressure. The second test is sustained pressure test at a hoop stress of 4,200 PSI. 2220 Northmont PKWY Suite 250 Duluth, GA 30096 T: 1+ 678 473-1185 F: 1+ 678 417-6273 E: [email protected] • After the pipe has been joined, fill it with water, carefully bleed off any trapped air. Shop Grainger today for the pipe and test plugs you need to help repair and test water, sewer and general plumbing systems. The system protects the restraint mechanism - comprised of a grip ring, Rieber gasket and casing - from corrosion in the bell and spigot. The test duration shall be 2 hours. The length of fire hydrant laterals and service lines are not included in the overall length of pipe in determining the allowable leakage. ASTM F2164-18, Standard Practice for Field Leak Testing of Polyethylene (PE) and Crosslinked Polyethylene (PEX) Pressure Piping Systems Using Hydrostatic Pressure, ASTM International, West Conshohocken, PA, 2018, www. PIPE PLUG, MECHANICAL, NIGHT CAP, SPIGOT END, 8" DIA DI/C900 Nominal Pipe Size: 8" (203mm NEVER use a test pressure greater than the capacity of the weakest. The tap shall be made at the top of pipe. Each length of pipe shall be proof tested in accordance with Sec. Through 60 In. Schedule 80 PVC and CPVC Schedule 40 PVC Technical Manual Piping Systems. through 212 in. In plan layout of pressure networks, when drawing a pipe you can enter to draw a curve, the same way as when you draw a polyline for curved segments. Blue Brute™ water pipe has the long-term hydrostatic strength to meet the high safety requirements commonly needed by municipal water systems. AWWA C900 – Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. Pressure classes range from 80 psi (550 kPa) to 305 psi (2,100 kPa).